Manage data your way.

Whether you’re connecting the Sentec Digital Monitor to other devices in your existing infrastructure, generating customized patient reports, or initiating remote monitoring, find out how Sentec enables safe and reliable data and connectivity solutions.

Manage data your way.

Whether you’re connecting the Sentec Digital Monitor to other devices in your existing infrastructure, generating customized patient reports, or initiating remote monitoring, find out how Sentec enables safe and reliable data and connectivity solutions.

Manage data your way.

Whether you’re connecting the Sentec Digital Monitor to other devices in your existing infrastructure, generating customized patient reports, or initiating remote monitoring, find out how Sentec enables safe and reliable data and connectivity solutions.

*Note: This is a global overview and may contain information on products not released in all markets/countries. Information is subject to change without notice.

Patient Monitoring Systems (PMS)

Ascom

Digistat® Smart Central

  • Digistat Suite 8.0 or higher
  • Sentec SMI Driver Version 1.1.10 or higher

Digistat® Smart Central:

  • V08.04.x
  • V08.05.x

Digistat® Smart Central:

  • tcPCO2
  • TcPO2*
  • SpO2
  • PR
  • Trend data display

*PO₂ monitoring is only supported if PO₂ channel is enabled and OxiVentTM sensor is connected

Digistat® Smart Central:

LAN

  • LAN cable required
Dräger: Infinity®

Infinity® Delta, Infinity® Delta XL, Infinity® Kappa, Infinity® Omega Series:

  • V07.xx.x
  • V08.00.x
  • V08.01.x
  • V08.02.x
  • V08.03.x
  • V08.04.x
  • V08.05.x

Infinity® Delta, Infinity® Delta XL, Infinity® Kappa, Infinity® Omega Series:

  • tcPCO2
  • tcPO2

*PO₂ monitoring is only supported if PO₂ channel is enabled and OxiVentTM sensor is connected

Infinity® Delta, Infinity® Delta XL, Infinity® Kappa, Infinity® Omega Series:

Serial Interface Protocol

  • TCB-Protocol
GE Healthcare: Carescape, Solar, Dash
  • Carescape B450: V2
  • Carescape B650: V1
  • Carescape B850: V1
  • Solar 8000 M: V4A
  • Solar 8000 i: V4E
  • Dash 5000: V3A

Carescape B450, Carescape B650, Carescape B850, Solar 8000 M, Solar 8000 i, Dash 5000:

  • V08.00.x
  • V08.01.x
  • V08.02.x
  • V08.03.x
  • V08.04.x
  • V08.05.x

Carescape B450, Carescape B650, Carescape B850, Solar 8000 M, Solar 8000 i, Dash 5000:

  • tcPCO2
  • TcPO2*
  • SpO2
  • PR

*PO₂ monitoring is only supported if PO₂ channel is enabled and OxiVentTM sensor is connected

Carescape B450, Carescape B650, Carescape B850, Solar 8000 M, Solar 8000 i, Dash 5000:

Serial Interface Protocol

  • SentecLink

Baud rate

  • 19200
Mindray: Beneview, Benevision
  • BeneView T5/T6/T8/T9: 5.25 or higher
  • BeneVision N12, N15, N17, N19, N22: V2.0 or higher

BeneView T5/T6/T8/T9, BeneVision N12, N15, N17, N19, N22:

  • V08.00.x
  • V08.01.x
  • V08.02.x
  • V08.03.x
  • V08.04.x
  • V08.05.x

BeneView T5/T6/T8/T9, BeneVision N12, N15, N17, N19, N22:

  • tcPCO2
  • TcPO2*
  • SPO2
  • PR
  • Trend data display

*PO₂ monitoring is only supported if PO₂ channel is enabled and OxiVentTM sensor is connected

BeneView T5/T6/T8/T9, BeneVision N12, N15, N17, N19, N22:

Serial Interface Protocol

  • SentecLink

Baud rate

  • 115200
Philips: IntelliVue
  • IntelliVue MP 40/50/60/70/80/90 or MX600/700/800 via VueLink Interface: All SW Versions
  • IntelliVue MP40/50/60/70/80/90 or MX600/700/750/800/850 with IntelliBridge EC10: H.15 or higher
  • IntelliVue MX400/450/500/550 with IntelliBridge EC10: All SW Versions

IntelliVue MP 40/50/60/70/80/90 or MX600/700/800/850 via VueLink Interface:

  • V07.xx.x
  • V08.00.x
  • V08.01.x
  • V08.02.x
  • V08.03.x
  • V08.04.x
  • V08.05.x

IntelliVue MP40/50/60/70/80/90 or MX600/700/750/800 with IntelliBridge EC10:

  • V07.xx.x
  • V08.00.x
  • V08.01.x
  • V08.02.x
  • V08.03.x
  • V08.04.x
  • V08.05.x

IntelliVue MX400/450/500/550 with IntelliBridge EC10:

  • V07.xx.x
  • V08.00.x
  • V08.01.x
  • V08.02.x
  • V08.03.x
  • V08.04.x
  • V08.05.x

IntelliVue MP 40/50/60/70/80/90 or MX600/700/800 via VueLink Interface,

IntelliVue MP40/50/60/70/80/90 or MX600/700/750/800/850 with IntelliBridge EC10,

IntelliVue MX400/450/500/550 with IntelliBridge EC10:

  • tcPCO2
  • TcPO2*
  • SpO2
  • PR

* PO₂ monitoring is only supported if PO₂ channel is enabled and OxiVentTM sensor is connected.

IntelliVue MP 40/50/60/70/80/90 or MX600/700/800 via VueLink Interface,

IntelliVue MP40/50/60/70/80/90 or MX600/700/750/800/850 with IntelliBridge EC10,

IntelliVue MX400/450/500/550 with IntelliBridge EC10:

Serial Interface Protocol

  • Philips Vuelink/Intellibridge 1/2
Spacelabs Healthcare: Flexport
  • Flexport System UltraView SL (90442A-03): V2.00.02EN

Flexport System UltraView SL (90442A-03):

  • V07.xx.x
  • V08.00.x
  • V08.01.x
  • V08.02.x
  • V08.03.x
  • V08.04.x
  • V08.05.x

Flexport System UltraView SL (90442A-03):

  • tcPCO2
  • SpO2
  • PR
  • Trend data display

Flexport System UltraView SL (90442A-03):

Serial Interface Protocol

  • Spacelabs Flexport

Patient Data Management Systems (PDMS)

Capsule: MDIP

Medical Device Information Platform (MDIP):

  • Sentec A5.x and higher

Medical Device Information Platform (MDIP):

  • V07.xx.x
  • V08.00.x
  • V08.01.x
  • V08.02.x
  • V08.03.x

Medical Device Information Platform (MDIP):

  • tcPCO2
  • tcPO2*
  • SpO2
  • PR

* PO₂ monitoring is only supported if PO₂ channel is enabled and OxiVentTM sensor is connected.

Medical Device Information Platform (MDIP):

Serial Interface Protocol

  • SentecLink

Baud rate

  • 115200 or lower
Dräger: Integrated Care Manager

Integrated Care Manager (ICM):

  • Version 9.2

Integrated Care Manager (ICM):

  • V08.00.x
  • V08.01.x
  • V08.02.x
  • V08.03.x
  • V08.04.x
  • V08.05.x
Integrated Care Manager (ICM):

  • tcPCO2
  • TcPO2*
  • SpO2
  • PR

* PO₂ monitoring is only supported if PO₂ channel is enabled and OxiVentTM sensor is connected.

Integrated Care Manager (ICM):

Serial Interface Protocol

  • SentecLink

Baud rate

  • 115200 or lower
iMDsoft: MetaVision

MetaVision:

  • V5 or higher

MetaVision:

  • V08.00.x
  • V08.01.x
  • V08.02.x
  • V08.03.x
  • V08.04.x
  • V08.05.x
MetaVision:

  • tcPCO2
  • TcPO2*
  • SPO2
  • PR

* PO₂ monitoring is only supported if PO₂ channel is enabled and OxiVentTM sensor is connected.

MetaVision:

Serial Interface Protocol

  • SentecLink

Baud rate

  • 115200
Stowood: Visi-Download

Visi-Download:

  • 140715 or higher

Visi-Download:

  • V08.00.x
  • V08.01.x
  • V08.02.x
  • V08.03.x
  • V08.04.x
  • V08.05.x

Visi-Download:

  • tcPCO2
  • tcPCO2 (drift corrected)
  • TcPO2*
  • SpO2
  • PR
  • Trend data display

* PO₂ monitoring is only supported if PO₂ channel is enabled and OxiVentTM sensor is connected.

Visi-Download:

Serial Interface Protocol

  • SentecLink

Baud rate

  • 115200 or lower
TZM

TZM (via) UMG to GE Healthcare’s patient monitors:

  • V1.0

TZM (via) UMG to GE Healthcare’s patient monitors:

  • V08.00.x
  • V08.01.x
  • V08.02.x
TZM (via) UMG to GE Healthcare’s patient monitors:

  • tcPCO2
  • TcPO2*

* PO₂ monitoring is only supported if PO₂ channel is enabled and OxiVentTM sensor is connected.

Serial Interface Protocol

TZM (via) UMG to GE Healthcare’s patient monitors:

  • SentecLink

Baud rate

TZM (via) UMG to GE Healthcare’s patient monitors:

  • 115200

Ventilators

Air Liquide: Vendom

Vendom 30/40:

  • V 2.05 or higher

Vendom 30/40:

  • V07.xx.x
  • V08.00.x
  • V08.01.x
  • V08.02.x
  • V08.03.x
  • V08.04.x

Vendom 30/40:

  • tcPCO2
  • SpO2
  • PR
  • Trend data display

Vendom 30/40:

Serial Interface Protocol

  • SentecLink

Baud rate

  • 115200
Breas: Vivo 45, Nippy
  • Vivo 45: 1.0.33 or higher
  • Vivo 45 LS: 3.0.44 or higher
  • Vivo 45 L (US): 5.0.01 or higher
  • Nippy 4+: 4.0.51 or higher

Vivo 45, Vivo 45 LS, Vivo 45 L (US), Nippy 4+:

  • V07.xx.x
  • V08.00.x
  • V08.01.x
  • V08.02.x
  • V08.03.x
  • V08.04.x

Vivo 45, Vivo 45 LS, Vivo 45 L (US), Nippy 4+:

  • tcPCO2
  • Trend data display

Vivo 45, Vivo 45 LS, Vivo 45 L (US), Nippy 4+:

Serial Interface Protocol

  • SentecLink

Baud rate

  • 57600
EOVE: EO-150

EO-150:

  • V 5.0.0 or higher

EO-150:

  • V08.00.x
  • V08.01.x
  • V08.02.x
  • V08.03.x
  • V08.04.x
  • V08.05.x

EO-150:

  • tcPCO2
  • tcPCO2 (drift corrected)
  • SPO2
  • PR
  • Trend data display

EO-150:

Serial Interface Protocol

  • SentecLink

Baud rate

  • 115200
Philips: Trilogy, A30, A40
  • Trilogy Evo, Trilogy Evo O2, Trilogy EV300: 1.06.02.00 or higher
  • A30 EFL, A40 Pro, A40 EFL: 1.1.0.0 and higher

Trilogy Evo, Trilogy Evo O2, Trilogy EV300, A30 EFL, A40 Pro, A40 EFL:

  • V08.00.x
  • V08.01.x
  • V08.02.x
  • V08.03.x
  • V08.04.x
  • V08.05.x

Trilogy Evo, Trilogy Evo O2, Trilogy EV300:

  • tcPCO2
  • Trend data display

A30 EFL, A40 Pro, A40 EFL:

  • tcPCO2
  • SpO2
  • PR
  • Trend data display

Trilogy Evo, Trilogy Evo O2, Trilogy EV300:

Serial Interface Protocol

  • SentecLink

Baud rate

  • 19200

A30 EFL, A40 Pro, A40 EFL:

Serial Interface Protocol

  • SentecLink

Baud rate

  • 115200
Thora Tech: Monsoon 4
  • Monsoon 4: 1.0 or higher
  • Remote Display: 1.0 or higher

Monsoon 4 via remote display:

  • V08.00.x
  • V08.01.x
  • V08.02.x
  • V08.03.x
  • V08.04.x
  • V08.05.x

Monsoon 4 via remote display:

  • tcPCO2
  • SpO2
  • PR
  • Trend data display

Monsson 4 via remote display:

Serial Interface Protocol

  • SentecLink

Baud rate

  • 115200 or lower

Download the Thora Tech guide and manual:

Digital Connectivity to PG/PSG

Cidelec

CID102L, CID102LB, CID-LXe, CID-LXe-206d, CID-LX, CID-LX-206d:

  • 2.2.4 or higher

CID102L, CID102LB, CID-LXe, CID-LXe-206d, CID-LX, CID-LX-206d:

  • V07.xx.x
  • V08.00.x
  • V08.01.x
  • V08.02.x
  • V08.03.x
  • V08.04.x
  • V08.05.x

CID102L, CID102LB, CID-LXe, CID-LXe-206d, CID-LX, CID-LX-206d:

  • tcPCO2
  • tcPCO2 (drift corrected)
  • SpO2
  • PR
  • Trend data display

CID102L, CID102LB, CID-LXe, CID-LXe-206d, CID-LX, CID-LX-206d:

Serial Interface Protocol

  • SentecLink

Baud rate

  • 115200
Nox Medical
  • NOX A1: FW 1.1.6 and Noxturnal 5.1.3
  • NOX A1s (via C1): FW 3.0.9 and Noxturnal 6.3.1 or higher
  • NOX C1: FW 1.1.0 and Noxturnal 6.0.0 or higher
  • NOX T3: FW 1.6.1 and Noxturnal 5.1.3

NOX A1, NOX A1s (via C1), NOX C1, NOX T3:

  • V08.00.x
  • V08.01.x
  • V08.02.x
  • V08.03.x
  • V08.04.x
  • V08.05.x

NOX A1, NOX A1s (via C1), NOX C1, NOX T3:

  • tcPCO2
  • TcPO2*
  • SpO2
  • PR
  • Trend data display

* PO₂ monitoring is only supported if PO₂ channel is enabled and OxiVentTM sensor is connected.

NOX A1, NOX A1s (via C1), NOX C1, NOX T3:

Serial Interface Protocol

  • SentecLink

Baud rate

  • 115200

NOX A1s (via C1), NOX C1: LAN integration possible (alternative)

Analog Connectivity to Polygraphic and Polysomnographic Systems (PG/PSG)

Sentec offers a variety of adapter cables to connect PG/PSG systems via analog interface.

  • Carefusion
    • SomnoStar Pro: PSG Cable E
  • Cidelec
    • CID102L8-D: PSG Cable P
  • Compumedics
    • E-Series: PSG Cable E
    • Grael: PSG Cable E
    • Grael 4k: PSG Cable E
    • Siesta: PSG Cable G
    • Somte: PSG Cable E
  • Fenyves & Gut/Löwenstein Medical
    • SleepDoc Porti 7 (PG): PSG Cable D
    • SleepDoc Porti 8 (PSG): PSG Cable D
    • MiniScreen PRO (PSG): PSG Cable D
    • MiniScreen plus (PG): PSG Cable D
    • Sonata: PSG Cable B
  • Natus
    • Comet / Aurora: PSG Cable E
    • Comlab: PSG Cable H
    • Deltamed Brain Box: PSG Cable J
    • Deltamed Duo 44: PSG Cable H
    • Embletta Gold: PSG Cable L
    • Embletta MPR PG: PSG Cable L
    • Embla NDx: PSG Cable F
    • Embla SDx: PSG Cable E
    • Embla S7000 / N7000: PSG Cable A
    • Embla Titanium (Isolation Box): PSG Cable E
    • Embla Titanium: PSG Cable K
    • Mdrive: PSG Cable N
    • TX Proxy: PSG Cable N
    • PAIB2 interface box: PSG Cable F
  • Neurovirtual
    • Sleepvirtual: PSG Cable E
    • BWII (SI1089)**: PSG Cable E
    • BWIII: PSG Cable E
  • SOMNOmedics
    • SOMNOscreen (SSC082)**: PSG Cable Q
    • SOMNOscreen plus (SSC082)**: PSG Cable Q
  • Stowood Scientific Instruments
    • Visi-3: PSG Cable E
    • Visi-System: PSG Cable E
  • Philips Respironics
    • Alice 3 / 4 / 5 / 6 (square plug): PSG Cable B
    • Alice 3 / 4 / 5 / 6 (round plug): PSG Cable F
  • Weinmann_MCC
    • SOMNOlab: PSG Cable C
    • SOMNOlab2: PSG Cable C
  • Please refer to the Sentec Digital Monitor (SDM) Menu ‘Interfaces/Analog Outputs’ for ‘Channel-to-Parameter’ assignment information.
  • For instructions to interface the SDM with polygraphic or polysomnographic systems please refer to the respective manufacturer’s instructions for use and to the chapter ‘Analog Outputs’ in the Technical Manual for the SDM (HB-005752).
  • The Technical Manual is available as a PDF on our website under https://www.sentec.com/ifu 

** Product number of accessory cables or optocoupler required for installation in brackets behind the product name

For more help with Sentec connectivity please email: connectivity@sentec.com

Analog Connectivity to Polygraphic and Polysomnographic Systems (PG/PSG)

Sentec offers a variety of adapter cables to connect PG/PSG systems via analog interface.

  • Carefusion
    • SomnoStar Pro: PSG Cable E
  • Cidelec
    • CID102L8-D: PSG Cable P
  • Compumedics
    • E-Series: PSG Cable E
    • Grael: PSG Cable E
    • Grael 4k: PSG Cable E
    • Siesta: PSG Cable G
    • Somte: PSG Cable E
  • Fenyves & Gut/Löwenstein Medical
    • SleepDoc Porti 7 (PG): PSG Cable D
    • SleepDoc Porti 8 (PSG): PSG Cable D
    • MiniScreen PRO (PSG): PSG Cable D
    • MiniScreen plus (PG): PSG Cable D
    • Sonata: PSG Cable B
  • Natus
    • Comet / Aurora: PSG Cable E
    • Comlab: PSG Cable H
    • Deltamed Brain Box: PSG Cable J
    • Deltamed Duo 44: PSG Cable H
    • Embletta Gold: PSG Cable L
    • Embletta MPR PG: PSG Cable L
    • Embla S7000 / N7000: PSG Cable A
    • Embla Titanium (Isolation Box): PSG Cable E
    • Embla Titanium: PSG Cable K
    • Mdrive: PSG Cable N
    • TX Proxy: PSG Cable N
    • PAIB2 interface box: PSG Cable F
  • Neurovirtual
    • Sleepvirtual: PSG Cable E
    • BWII (SI1089)**: PSG Cable E
    • BWIII: PSG Cable E
  • SOMNOmedics
    • SOMNOscreen (SSC082)**: PSG Cable Q
    • SOMNOscreen plus (SSC082)**: PSG Cable Q
  • Stowood Scientific Instruments
    • Visi-3: PSG Cable E
    • Visi-System: PSG Cable E
  • Philips Respironics
    • Alice 3 / 4 / 5 / 6 (square plug): PSG Cable B
    • Alice 3 / 4 / 5 / 6 (round plug): PSG Cable F
  • Weinmann_MCC
    • SOMNOlab: PSG Cable C
    • SOMNOlab2: PSG Cable C
  • Please refer to the Sentec Digital Monitor (SDM) Menu ‘Interfaces/Analog Outputs’ for ‘Channel-to-Parameter’ assignment information.
  • For instructions to interface the SDM with polygraphic or polysomnographic systems please refer to the respective manufacturer’s instructions for use and to the chapter ‘Analog Outputs’ in the Technical Manual for the SDM (HB-005752).
  • The Technical Manual is available as a PDF on our website under https://www.sentec.com/ifu 

** Product number of accessory cables or optocoupler required for installation in brackets behind the product name

For more help with Sentec connectivity please email: connectivity@sentec.com